URSA M-25

Soft, lightweight glasswool mats are designed to insulate hot water pipelines and process equipment.

more
thumbnail URSA M-25 - soft, lightweight glasswool mats are designed to insulate hot water pipelines and process equipment.

URSA M-25Ф - mats covered with aluminum foil.

Application:
  • Thermal insulation of pipelines
  • Acoustic insulation for air ducts
  • Technical insulation of industrial equipment
  • Technical parameters

    Thickness
    50-100 mm
    Width
    1200 mm
    Length
    depending on thickness
    Thermal Conductivity in 10 °C, λ10
    0,034 W/mK
    Thermal Conductivity in 25 °C, λ25
    0,037 W/mK
    Service temperature
    -60...+350 °С
    Reaction to fire
    A1 (non-combustible)

    URSA M-11

    Soft glasswool rolls designed for use in non-loaded horizontal structures.

    more
    thumbnail URSA M-11 - soft glasswool rolls designed for use in non-loaded horizontal structures.

    URSA M-11Ф - glasswool mats coated with aluminum foil.

    Application:
  • Flat roofs
  • partition walls
  • framed external walls
  • Technical insulation of pipelines, air ducts, industrial equipment
  • Technical parameters

    Thickness
    50-100 mm
    Width
    1200 mm
    Length
    depending on thickness
    Thermal Conductivity in 10 °C, λ10
    0,039 W/mK
    Thermal Conductivity in 25 °C, λ25
    0,042 W/mK
    Service temperature
    -60...+320 °С
    Reaction to fire
    A1 (non-combustible)

    URSA M-15

    Tthermal and acoustic insulation for pitched roofs, prefabricated timber walls and other applications.

    more
    thumbnail URSA M-15 - is thermal and acoustic insulation for pitched roofs, prefabricated timber walls and other applications.
    Application:
  • pitched roofs
  • prefabricated timber walls
  • partition walls
  • technical insulation of pipelines, air ducts, industrial equipment
  • Technical parameters

    Thickness
    50-100 mm
    Width
    1200 mm
    Length
    depending on thickness
    Thermal Conductivity in 10 °C, λ10
    0,037 W/mK
    Thermal Conductivity in 25 °C, λ25
    0,040 W/mK
    Service temperature
    -60...+320 °С
    Reaction to fire
    A1 (non-combustible)

    Tank slab GW40

    Heat insulating glasswool products rectangular in shape and cross-section. Tank slab GW40 may come with glass-fibre mat coating.

    more
    thumbnail Tank slab GW40 - Heat insulating glasswool products rectangular in shape and cross-section. Tank slab GW40 may come with glass-fibre mat coating.

    Application: Heat sound insulation of the process equipment (including ventilation systems, water, oil and petroleum product storage tanks), including for insulation of convoluted surfaces of over 250 mm in radius.

    Technical parameters

    Length
    1200 mm
    Width
    1200 mm
    Thickness
    50-150 mm
    Density
    33-44 kg/m3
    Thermal Conductivity in 10 °C, λ10
    0,035 W/m*K
    Thermal Conductivity in 25 °C, λ25
    0,037 W/m*K
    Thermal Conductivity in 50 °C, λ50
    0,041 W/m*K
    Thermal Conductivity in 100 °C, λ100
    0,048 W/m*K
    Thermal Conductivity in 125 °C, λ125
    0,052 W/m*K
    Thermal Conductivity in 150 °C, λ150
    0,061 W/m*K
    Thermal Conductivity in 200 °C, λ200
    0,079 W/m*K
    Thermal Conductivity in 250 °C, λ250
    0,097 W/m*K
    Thermal Conductivity in 300 °C, λ300
    0,115 W/m*K
    Fire hazard class
    КМ0 (KM1)
    Flammability group
    Noncombustible (Combustible)
    Maximum operating temperature
    +350°С

    HVAC slab-T

    Heat insulating glasswool products rectangular in shape. Come glass cloth-coated.

    more
    thumbnail HVAC slab-T - Heat insulating glasswool products rectangular in shape. Come glass cloth-coated.

    Application:
    - Heat sound insulation in the ventilation systems (including in attenuators of the noise emitted by ventilation and airconditioning systems), in household, industrial and process equipment.
    - As sound-absorbing materials of pipe-like and plate-like mufflers.
    - As indoor sound-absorbing materials, sound absorbent linings and sound shields, including for creation of friendly acoustics in cinemas and concert halls.
    - Insulation of structure members and equipment of sea vessels and floating structures.

    Technical parameters

    Length
    1200 mm
    Width
    1200 mm
    Thickness
    30-100 mm
    Density
    45-55 kg/m3
    Thermal Conductivity in 10 °C, λ10
    0,032 W/m·К
    Thermal Conductivity in 25 °C, λ25
    0,035 W/m·К
    Thermal Conductivity in 50 °C, λ50
    0,038 W/m·К
    Thermal Conductivity in 100 °C, λ100
    0,045 W/m·К
    Thermal Conductivity in 125 °C, λ125
    0,048 W/m·К
    Thermal Conductivity in 150 °C, λ150
    0,053 W/m·К
    Thermal Conductivity in 200 °C, λ200
    0,062 W/m·К
    Thermal Conductivity in 250 °C, λ250
    0,071 W/m·К
    Thermal Conductivity in 300 °C, λ300
    0,080 W/m·К
    Fire hazard class
    КМ1
    Flammability group
    Combustible
    Maximum operating temperature
    +540°С

    HVAC slab

    Heat insulating glasswool products rectangular in shape.

    more
    thumbnail HVAC slab - Heat insulating glasswool products rectangular in shape.

    Application:
    - Heat sound insulation in the ventilation systems (including in attenuators of the noise emitted by ventilation and airconditioning systems), in household, industrial and process equipment.
    - As sound-absorbing materials of pipe-like and plate-like mufflers.
    - As indoor sound-absorbing materials, sound absorbent linings and sound shields, including for creation of friendly acoustics in cinemas and concert halls.
    - Insulation of structure members and equipment of sea vessels and floating structures.

    Technical parameters

    Length
    1200 mm
    Width
    1200 mm
    Thickness
    30-100 mm
    Density
    45-55 kg/m3
    Thermal Conductivity in 10 °C, λ10
    0,032 W/m·К
    Thermal Conductivity in 25 °C, λ25
    0,035 W/m·К
    Thermal Conductivity in 50 °C, λ50
    0,038 W/m·К
    Thermal Conductivity in 100 °C, λ100
    0,045 W/m·К
    Thermal Conductivity in 125 °C, λ125
    0,048 W/m·К
    Thermal Conductivity in 150 °C, λ150
    0,053 W/m·К
    Thermal Conductivity in 200 °C, λ200
    0,062 W/m·К
    Thermal Conductivity in 250 °C, λ250
    0,071 W/m·К
    Thermal Conductivity in 300 °C, λ300
    0,080 W/m·К
    Fire hazard class
    КМ0
    Flammability group
    Noncombustible
    Maximum operating temperature
    +350°С




      8 (800) 707-53-99 Звонок по России бесплатный
      firm@sevren.ru